TM 5-6350-275-24&P
(7) Close the front access door on enclosure (14) and secure.
3-90.
REPLACE J-SIIDS MODS II MODEM PWA ASSEMBLY. (See Figure 3-45).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Wear ESD wriststrap while working on
equipment.
Materials/Parts:
Mod II Modem PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Replace
(1) Remove slip-on terminal strip from Stargate 1000 PWA, TB-1 (7).
(2) Tag and remove wires from J1 (17) and J2 (18) by lifting up on terminal strips.
(3) Press out on one side of snap track PWA holder (*) and remove the Mod2 II Modem PWA (2) from snap
track PWA holder slots.
(4) Place the removed PWA into ESD protective bag.
b. Installation
(1) Set the link setting and/or switch setting exactly the same as removed assembly or refer to Appendix E,
page E-52, PWA settings.
(2) Press out on sides of snap track PWA holder (*) and install Mod2 II Modem (2) in snap track alignment
slots and release.
(3) Connect the tagged wires to J1 (17) and J2 (18).
(4) Connect the slip-on terminal strip to Stargate 1000 PWA, TB-1 (7).
(5) Reconnect input power.
(6) Close the front access door on enclosure and secure.
3-177
|