TM 5-6350-275-24&P
3-89.
REPLACE J-SIIDS STARGATE 1000 PWA ASSEMBLY. (See Figure 3-45).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Wear ESD wriststrap while working on
Tools:
equipment.
Screwdriver, flat tip, (Item 7, App B)
Materials/Parts:
Stargate 1000 PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Replace
(1) Tag and remove cable connectors from Comms jack (13) and AUX-0 jack (12) by lifting straight up on
connectors.
(2) Remove slip-on terminal strips from TB-50 (11), TB-7 (10), TB-8 (9), TB-9 (8) and TB-1 (7) by lifting up on
terminal strips.
(3) Using a flat tip screwdriver, remove the green ground wire (14) and screw (15) from Stargate 1000 PWA
(1).
(4) Press in and hold latching mechanism (16) down on each plastic standoff (**), while gently lifting up on
Stargate PWA (1). Do this for each of the five latching mechanisms until the PWA can be removed from
panel assembly (5).
(5) Place the removed Stargate PWA into a ESD protective bag.
b. Installation
(1) Set the link settings and/or switch settings exactly the same as on removed assembly, or refer to Appendix
E, page E-33 for PWA settings.
(2) Place the Stargate PWA (1) on plastic standoffs and gently press down on PWA until each of the latching
mechanism locks into place.
(3) Connect green ground (14) wire to Stargate PWA using removed screw (15).
(4) Connect slip-on terminal strips to TB-1 (7), TB-7 (10), TB-8 (9) and TB-9 (8) and TB-50 (11).(Ensure each
terminal strip is properly lined up with terminal pins)
(5) Connect the tagged nine pin male connectors to Comms jack (13) and AUX-0 jack (12).
(6) Reconnect input power.
3-176
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |