|
|
TM 5-6350-275-24&P
3-61. REPLACE RADC ENCLOSURE TAMPER SWITCH. (Figure 3-40).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Enclosure cover removed
Remove all jewelry while working
on equipment.
Tools:
Screwdriver, Flat tip (Item 6, App B)
Wear ESD wriststrap while
working on equipment.
Materials/Parts:
Tamper switch
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Remove the two slip-on terminal lugs (4) from the tamper switch (3).
(2) Using a flat tip screwdriver remove the two screws (6) and washers (5) holding the tamper switch (3) to
enclosure mount.
b. Installation
(1) Align the tamper switch (3) up with enclosure mount and secure with two screws (6) and washers (5).
(2) Connect the slip-on terminal lugs to tamper switch terminals (4) common and normal open (NO).
(3) Connect AC adapter to power source.
(4) Place front access cover on enclosure and secure.
3-143
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |