Table 7-1. Control Unit Performance Standards - Continued
Control Setting
Step
Test
Performance
No.
Test
Equipment
Procedure
Standard
Equipment
Under Test
f. Momentarily dis-
a. Sonalert should
connect orange
sound (for 10 2
jumper wire from
seconds).
terminal A-L.
Operating mode
g. Momentarily dis-
a. Meter should in-
switch: SECURE
connect orange
dicate more than
jumper wire from
100,000 ohms (for
terminal A-I.
10 2 seconds).
POWER: OFF
h. None.
a. Meter should in-
indicate more than
100,000 ohms.
10
TS352B: R X 100
POWER: ON
a. Connect TS352B
a. Meter should in-
(zero meter)
Operating mode
test leads be-
dicate less than
switch: SECURE
tween terminals
2000 ohms.
LATCH/NON LATCH:
S1-D and -DR.
Stopwatch
NON LATCH
b. Momentarily dis-
a. Meter should in-
connect orange
dicate more than
jumper wire from
100,000 ohms for
terminal F-I.
10 2 seconds.
c. Depress enclo-
a. Meter should in-
sure tamper
dicate more than
switch to the
100,000 ohms (for
alarm position
10 2 seconds).
and then return
it to the alarm
bypass position.
d. Momentarily dis-
a. Meter should in-
connect orange
dicate more than
jumper wire from
100,000 ohms (for
terminal A-I.
10 2 seconds)
after expiration
of the entrance
time delay (8 to
100 seconds).
Operating mode
e. Momentarily dis-
a. Meter should in-
switch: TEST/
connect orange
dicate more than
RESET
jumper wire from
100,000 ohms (for
terminal A-1.
10 2 seconds).
11
TS352B: R X 100
POWER: ON
a. Connect TS352B
a. Meter should in-
(zero meter)
Operating mode
test leads be-
dicate less than
switch: TEST/
tween terminals
2000 ohms.
RESET then
S1-D and -DR.
SECURE
b. Momentarily dis-
a. Meter should in-
LATCH/NON LATCH:
connect orange
dicate more than
LATCH
jumper wire from
100,000 ohms until
terminal F-1.
reset (step c).
Operating mode
c. Depress enclo-
a. Meter should in-
switch: TEST/
sure tamper
dicate more than
RESET then
switch to the
100,000 ohms until
SECURE
alarm position
reset (step d).
-then return it to
the alarm bypass
position.
Operating mode
d. Disconnect orange
a. None.
switch: TEST/
jumper wire from
RESET
terminal A-I.
7-17