TM 5-5420-205-14
c. Refer to figure 4-9 for removal and installation of
of 3,000 psi, proof pressure is 3,500 psi, and zero
check valve, pilot operated (located on interior bay
external leakage at 3,000 psi. Valve size is 1/3 inch.
model no. 2272). This valve has an operating pressure
Figure 4-9. Pilot operated check valve. interior bay model
no. 2272, removal and installation.
4-12
|