TM 43-0156
Step
Function
Mech
Insp
2
(4)
Ground Rods. Place ground rods in a PPP-B-601 box
cont
(75-1/2 x 4-1/4 x 4-1/4) fabricated in accordance
with appendix D-1. Refer to table B-3-5 for a list
of materials. Mark box to identify contents.
(5)
Aspirator Gaskets. Tape each gasket to a piece of
PPP-F-320 fiberboard (32 x 32). Place gaskets in a
fiberboard box (32-1/4 x 32-1/4 x 2). Seal box with
PPP-T-76 tape. Mark box to identify contents.
(6)
Fluorescent Lamps. Cushion lamps with PPP-C-843
cushioning and secure in place with PPP-T-60 tape.
(7)
Electrolyte.
(a) Fabricate a PPP-B-601 box (58-1/2 x 32-1/4 x
21-1/4) in accordance with appendix D-1. Refer to
(b) Fill bottom of box with 3 inches of HH-I-585
thermal insulation.
(c) Place the containers of electrolyte, spaced 3
inches between each container on top of the
insulation.
(d) Fill void with HH-I-585 thermal insulation to the
level of the top edge of the wooden box.
(e) Close and secure box lid and mark box to identify
contents.
(8)
Electrical Fittings.
(a) Place the 12 bolt-on terminals in a MIL-B-131 bar-
rier bag (12 x 12) and heat seal. Mark bag to
identify contents.
(b) Place the 10 copper split-bolt connectors in a
MIL-B-131 barrier bag (12 x 12) and heat seal.
Identify bag contents.
(c) Place the 30 lugs with blank tongue in a MIL-B-131
barrier bag (12 x 20) and heat seal. Mark bag to
identify contents.
(d) Place the 500 nylon female quick disconnect termi-
nals in a MIL-B-131 barrier bag (20 x 25) and heat
seal. Mark bag to identify contents.
B-3-17
|