TM 43-0156
Step
Function
Mech
Insp
2
(f)
Atomize spray the interior of the tanks with
cont
MIL-L-21260, type I, grade 30 preservative oil
using a flexible nozzle of sufficient length to
assure coverage of all interior surfaces of the
tanks.
(g)
Install float covers.
(h)
Allow the tanks to stand, with the drain plugs
removed, until the preservative oil flow ceases.
(i)
Coat drain plugs with the same preservative oil
and install.
(j)
Seal fuel tank vent hole with MIL-T-22085 tape.
PPP-T-60, type 4, 4-inch wide tape, may be used
as a substitute.
(8) Engine Mounted Air Tank.
(a)
Open drain cocks.
(b)
Atomize spray interior surfaces with MIL-L-21260,
type I, grade 30 preservative oil.
(c)
Allow excess preservative to drain and leave drain
cocks open.
(9) Air Start Motor.
(a)
Fill the oiler with MIL-L-21260, type I, grade 30
preservative oil and reset metering valve.
(b)
Seal all starting motor openings with MIL-T-22085
tape. PPP-T-60, type 4, 4-inch wide tape, may be
used as a substitute.
(10) Governor.
(a)
Coat linkages, pins, and other metallic devices not
enclosed with MIL-G-10924 preservative grease.
(b)
Wrap or cover the governor with MIL-B-121 barrier
and secure the barrier with PPP-T-60 tape.
(11) Fan Belt.
(a)
Remove the fan belt.
(b)
Coat unpainted surfaces of pulley grooves with
TT-P-664 primer.
Change 1