Page Title: Louvered Radiator Openings (sides) (two).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 43-0156
Step
Function
Mech
Insp
(4) Secure plywood with removed bolts. Seal edges of
3
plywood panel with tape (7510-00-916-9659). NSN
cont
7510-00-890-9875 may be used as asubstitute.
j.
Louvered Radiator Openings (sides) (two).
(1) Close louvers.
(2) Remove 12 bolts evenly spaced from around louvers to
secure a plywood panel.
(3) Cover louvers with barrier (8135-00-282-0565) and
5/16-inch (86-1/2 x 55-1/2) plywood panel (5530-00-
618-6955). Drill holes in location of mounting bolts that
were removed. Plywood, 3/8-inch (5530-00-618-6956)
may be used as a substitute.
(4) Secure plywood panel with removed bolts.
(5) Seal edges of plywood panel with tape (7510-00-916-
9659). NSN 7510-00-890-9875 may be used as a sub-
stltute.
k.
Catwalk, Clevises, Exhaust Stacks, Ground Rods, Wire,
and Clamps.
(1) Secure catwalk in its raised position.
(2) Secure exhaust clamps to exhaust stacks.
(3) Secure exhaust stacks, clevises, and ground rods to
the catwalk with steel strapping (8135-00-283-0669).
Isolate the steel strapping with fiber-board. Secure
strapping with seals (8135-00-239-5293).
l.
Slings. Coat slings with corrosion preventive compound
m.
Bracing for Shipment.
(1) Air Filter Compartment. Place lumber (5510-00-220-
6214) (36 x 2-7/8 x 4) between air filter compartments
and the generator control cabinet.
(2) Control Cabinet. Brace the generator control cabinet
to the generator with 3-inch angle iron (9520-00-516-
5810). Bolt brace in place with existing bolts and lifting
eyes on generator.
(3) Radiator. Brace radiator to the floor with 3-inch
angle iron (9520-00-516-5810). Secure braces at a
45 angle from approximately two-thirds up on the
radiator to the floor.
Change 1
B-1-30

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business