TM 43-0156
Step
Function
Mech
Insp
2
PRESERVATION AND PACKING
NOTE
Preservatives specified herein and the
methods of application shall be in
accordance with MIL-P-116.
Diesel Engine.
a.
(I)
Coolant System.
(a)
Fill the coolant system to the proper level with
equal parts (by volume) of MIL-A-46153
antifreeze and clean water.
(b)
Prepare a UU-T-81 tag to indicate "COOLANT
SYSTEM
CONTAINS
WATER
AND
ANTIFREEZE IN EQUAL PARTS BY VOLUME
DO NOT DRAIN CHECK COOLANT LEVEL IF
COOLANT IS LOW, ADD COOLANT OF THE
SAME MIXTURE."
(c)
Attach the tag to the radiator sight glass.
(2)
Air Start System.
NOTE
The power plant may contain either an air or electric
starting system. No preservation is required for the
electric start.
(a)
Fill the oiler reservoir for the air starter with
MIL-L-21260, type I, grade 30 preservative oil.
(b)
Fully open the metering valve and run the air
starter until oil can be detected at the exhaust.
(3)
Fuel System.
(a)
Remove fuel gage float assembly. Preserve
assembly as follows:
1
Wrap float assembly in MIL-B-121 barrier,
cushion with PPP-C-843 cushioning, and place
into a PPP-B-636 fiberboard box (18 x 6 x 4).
Seal box with PPP-T-76 tape.