NAVAIR 17-15-50.4
TM 38-301-4
T.O. 33-1-37-4
CGTO 33-1-37-4
LABORATORY RECOMMENDATION CODES, NONAERONAUTICAL EQUIPMENT
CODE
GENERAL LAB RECOMMENDATIONS
A
Sample results normal; continue routine sampling.
X
Analysis results supplied to customer; no recommendation required.
Z
Previous recommendation still applies.
CODE
INSPECTION RECOMMENDATIONS (Requires Feedback)
H**
Inspect unit and advise lab of finding. Abnormal wear indicated by (PPM) (element).
Resample after (maintenance/*** hours/etc.)
K**
Impending failure, critical wear indicates by (element). Inspect unit and advise lab of findings.
Resample after (maintenance/*** hours/etc.).
L**
Inspect brake and clutch plate adjustments, change oil service filters, resample after *** hours
of operation.
M**
Perform engine coast-down check. If engine fails test, examine for discrepancy and advise
lab of results; otherwise, resample after *** hours of operation.
U**
Cooling system leak indicated by (Mg/Cr/Na/B). Inspect unit and advise lab of findings.
Resample after (maintenance/*** hours/etc.).
CODE
OIL CHANGE RECOMMENDATIONS (Requires Resample)
D
Change oil and service filters. Resample after *** hours of operation.
CODE
LAB REQUESTED RESAMPLES (Requires Resample)
B*
Resample as soon as possible; do not change oil.
C*
Resample after *** hours.
F*
Do not change oil. Submit sample after ground or test run. Do not operate until after receipt of
laboratory result or advice.
G*
Contamination suspected, do not change oil, resample unit and submit sample from new oil
servicing this unit
I*
Stop purification, resample each engine after 4 hours of operation.
N*
Unit 'wear-in' indicated; resample in accordance with break-in schedule or after *** hours.
P*
Do not operate; do not change oil; submit resample as soon as possible.
Q
Normal PPM was obtained from test cell run after complete P.E. where oil lubricated parts
were changed/removed/replaced. Monitor engine closely after installation to ensure a normal
trend before release to routine sampling.
NOTES:
*Resample (red cap) required
**Maintenance feedback required; advise laboratory of findings
***Laboratory will specify time limit
A-1
|