NAVAIR 17-15-50.1
TM 38-301-1
T.O. 33-1-37-1
CGTO 33-1-37-1
STANDARD LAB RECOMMENDATION CODES - NON AERONAUTICAL FOR SPECTROMETRIC ANALYSIS
(Not for Air Force Use)
CODE
GENERAL LAB RECOMMENDATIONS
A
Sample results normal; continue routine sampling.
X
Analysis results supplied to customer; no recommendation required.
Z
Previous recommendation still applies.
CODE
INSPECTION RECOMMENDATIONS (Requires Feedback)
H**
Inspect unit and advise lab of finding. Abnormal wear indicated by (element) (PPM).
Resample after (maintenance/***hours/etc.).
K**
Impending failure, critical wear indicated by (element). Inspect unit and advise lab of findings.
Resample after (maintenance/***hours/etc.).
L**
Inspect brake and clutch plate adjustments, change oil service filters, resample after *** hours
of operation.
M**
Perform engine coast-down check If engine fails test, examine for discrepancy and advise lab
of results, else resample after *** hours of operation.
U**
Cooling system leak indicated by (Mg/Cr/Na/B). Inspect unit and advise lab of findings.
Resample after (maintenance/***hours/etc.).
CODE
OIL CHANGE RECOMMENDATIONS (Requires Resample)
D
Change oil and service filters. Resample after *** hours of operation.
CODE
LAB REQUESTED RESAMPLES (Requires Resample)
B*
Resample as soon as possible; do NOT change oil.
C*
Resample after *** hours.
F*
Do not change oil; submit special sample after test run. Do not operate until after receipt of
laboratory results or advice.
G*
Contamination suspected; resample unit and submit sample from new oil servicing this unit.
N*
Unit 'wear-in' indicated; resample in accordance with break-in schedule or after *** hours.
I*
Stop purification resample each engine after 4 hours of operation.
P*
Do not operate; do not change oil; submit resample as soon as possible.
NOTES:
*Resample (red cap) required
**Maintenance feedback required; advise laboratory of findings
***Laboratory will specify time limit
A-2