TM 38-260
(d)
Applicable locking clamps or gibs shall be secured during test.
(c) Internal spindle tapers, when applicable, shall be checked and repaired as necessary to attain an
approximate 85 percent bearing contact, evenly distributed along the taper.
b. One copy of the document used to record the results of the analytical inspection shall be retained by the
maintenance activity in the job order folder and one copy shall be placed in the equipment's historical record folder.
7-3.
Analytical Test Patterns and Technical Maintenance Standards
a. Analytical test patterns (DGSC Form 900-1000 Series). Analytical test patterns differ from the TMSs.
(1) Analytical test patterns are used to determine the allowable tolerances, operational capability, and/or the
extent of maintenance required for machine serviceability. Examples of a test pattern for analytical inspection of
metalworking machinery are shown in figures 7-1 and 7-2.
7-4
|