(7) Install relay K4 (23) in accordance with paragraph 5-12c.
(8) Install RFI filter assembly A1 (6) in accordance with paragraph 5-11a.
(9) Replace high voltage shield (5) in accordance with paragraph 5-11b. Install top cover (2) and bottom
cover (3) in accordance with paragraph 5-11c.
(10) Refer to section V of this chapter.
e. Relay K1, K2, or K3 Removal and Replacement. Refer to figure 5-3 and proceed as follows:
(1) Remove top cover (2) and bottom cover (3) in accordance with paragraph 5-10a.
(2) Remove the high voltage shield (5) in accordance with paragraph 5-10b and RFI filter assembly A1
(6) in accordance with 5-10c, steps (1) through (4).
(3) Tag the terminal lugs (29) for proper identification during reconnection, then remove the nuts (28)
that secure the terminal lugs (29) to the relay (30) to be replaced.
(4) Remove the four screws (31), lock washers (32), flat washers (33), and standoffs (34). Remove the
relay to be replaced.
(5) Place the replacement relay in mounting position and secure to the component shelf (27) with the
four screws (31), lock washers (32), flat washers (33), and two standoffs (34).
(6) Attach each terminal lug (29) to the relay (30) as tagged and secure with the nuts (28).
(7) Replace RF1 filter assembly A1 (6) in accordance with paragraph 5-11a.
(8) Install the high-voltage shield (5) in accordance with paragraph 5-11b, then replace top cover (2) and
bottom cover (3) in accordance with paragraph 5-11c.
(9) Refer to section V of this chapter.
f. Filter FL1 through FL5 Removal and Replacement. Refer to 5-4 unless otherwise indicated and
proceed as follows:
(1) Remove bottom cover (3) (figure 5-3) in accordance with paragraph 5-10a.