TM 32-6110-003-24&P
Table 5-4. Power Distribution Box Troubleshooting Procedure - Continued
Step
Test Point
Test Equipment
Procedure
Normal Indication
If Indication is
If Indication is
Normal
Abnormal
6
J9-D, J10-G
Same as step 5.
a. Turn power supply on. Set circuit
breakers CB12 thru CB14 to on
(in) position. 28 V power supply
must be turned on. (See figure
5-3.)
0 V dc.
Replace relay K4 or
b.
Measure-  voltage  between
filter FL6.
connector pins J9-E (-) and J10-
G (+).
Proceed with step
Replace relay K4 or
c. Set FANS circuit breaker CB6 to
+28  V  dc.  Slowly
7.
filter FL6.
off (out) position and repeat step 6b.
bleeding down to 0
volts.
7
a. Turn power supply off.
b. Disconnect all test equipment.
Test Completed