Table 5-4. Power Distribution Box Troubleshooting Procedure
Step
Test Point
Test Equipment
Procedure
Normal Indication
If Indication is
If Indication is
Normal
Abnormal
NOTE
This procedure includes the major
components that may be defective
within the power distribution box.
The procedure does not test point-
to-point wiring within the power
distribution box.
Perform
measurement
checks
As
given
in
Proceed with step
Do not apply power
1
J1,J7,J2,J10,
described in paragraph 5-3.
2
to the unit.  Repair
J3,J6, J9,J11,
wiring and proceed
J5,J4
with step 2 when all
measurements  are
correct.
DC Input Tests
a. Verify all circuit breakers are set
Power  supply,
2
MISSION
to on (in) position and MISSION
POWER
ON
POWER switch is set to off
Connector
Indicator
(down) position.
assembly
P8,
Test cable W1
WARNING
Ground chassis before
applying power.
b. Turn power supply on and set for
+28 V dc output.