TM 32-5865-218-24&P
(2)
Remove four screws (82) and flat washers (83) that
secure connector bracket (66) to ECM bracket (36).
Tag and remove wires to connector, then remove connector
(3)
bracket from chassis.
To replace connector bracket, solder wires to connector a
(4)
marked during removal, then secure connector bracket (66)
to ECM bracket (36) with four screws (82) and flat
washers (83) .
Replace ECM bracket (36) in accordance
with paragraph 5-12t. Be careful not to damage connector
bracket wiring or ECM bracket wiring.
Refer to section V of this chapter.
(5)
Refer to figure 5-13 and
v.
Switch S1 Removal and Replacement.
proceed as follows:
Remove top cover (2) in accordance with paragraph 5-12a.
(1)
(2)
Tag the wires to identify switch (40) connections.
Remove the wires from the switch (40).
(3)
(4)
Remove the two screws (37) and lock washers (38) that
secure the switch bracket (39) to the rear of the chassis.
Remove the switch (40) and bracket (39) from the chassis.
Remove the two screws (41), four flat washers (42), and
(5)
two nuts (43) that secure the switch (40) to the bracket
(39).
To replace, aline the replacement switch with the bracket
(6)
(39) mounting holes and install the two screws (41), four
flat washers (42), and two nuts (43).
Aline the bracket (39) with the mounting holes on the
(7)
rear of the chassis (52) and install the two screws (37)
and lock washers (38) .
Attach the wires to the replacement switch as tagged.
(8)
Replace top cover in accordance with paragraph 5-12a.
(9)
(10) Refer to section V of this chapter.
w. Coax Switch Bracket Removal and Replacement. Refer to figure
cover (2) in accordance with paragraph 5-12a, then follow the proce-
dures listed in paragraph 5-12v, steps 4 and 5.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |