TM 32-5865-218-24&P
(2)
Identify relay to be replaced (32).
Tag wiring for proper reconnection, then remove heatshrink
(3)
tubing and unsolder wires from relay terminals.
(4)
Remove two screws (64), flat washers (65), and spacers
(74) that secure relay to ECM bracket (36) and remove
relay (32).
To replace relay, mount relay in place on ECM bracket
(5)
(36) and secure with two screws (64), flat washers (65),
and spacers (74).
Place length of 0.125 ID black heatshrink tubing (item 12,
(6)
App. D) over each wire, solder wires to relay terminals
Slide heatshrink tubing
as tagged during removal.
over connection and shrink.
Replace top cover in accordance with paragraph 5-12a.
(7)
Refer to section V of this chapter.
(8)
Refer to
s. Terminal Stud E1 through E5 Removal and Replacement.
Remove top cover (2) in accordance with paragraph 5-12a.
(1)
Tag all wiring connected to terminal stud (56) then
(2)
unsolder wiring.
Remove screw (75), flat washer (76), and two nylon
(3)
sleeves (80) that secure stud to ECM bracket (36) , then
Note that if terminal stud is used as a
remove stud.
ground (black wiring), nylon sleeves are not used.
To replace terminal stud, secure it to ECM bracket with
(4)
two nylon sleeves (80), flat washer (76) and screw
(75), then solder wiring as tagged during removal.
Replace top cover in accordance with paragraph 5-12a.
(5)
Refer to section V of this chapter.
(6)
Refer to figure 5-13
t. ECM Bracket Removal and Replacement.
and proceed as follows:
(1)
Remove top cover (2) in accordance with paragraph 5-12a.
(2) Remove terminal studs (81) in accordance with paragraph
Do not unsolder wiring.
Remove terminal board TB1 (29) in accordance with
(3)
Do not unsolder wiring.
|