TM 32-5865-216-24&P
Control Logic CCA A3 Test Point Signals
From
To
Signal
Test Point
U1-7
P1-31
MOTOR DIRECTION CONTROL
TP1
U1-7
MOTOR DIRECTION CONTROL
U3E-11
TP1
U1-7
U13B-1
MOTOR DIRECTION CONTROL
TP1
U1-7
MOTOR DIRECTION CONTROL
U13A-4
TP1
U2-4
U15-9
SHIFT REGISTER ENABLE
TP2
U3B-4
U2-2
MEM STB
TP3
U10A-2
U3B-4
MEM STB
TP3
U4B-4
U3F-12
TP4
U3F-12
U10C-9
TP4
U10D-12
U4B-3
MOTOR DRIVE CONTROL
TP5
U4B-3
U10C-10
MOTOR DRIVE CONTROL
TP5
U4B-3
U12A-2
MOTOR DRIVE CONTROL
TP5
P1-64
U4B-3
MOTOR DRIVE CONTROL
TP5
U11A-3
U10A-3
Motor drive counter reset B
TP6
U10B-6
U11A-4
Motor drive counter reset C
TP7
U2B-12
U11A-5
PWR ON RESET
TP8
U15-1
U2B-12
PWR ON RESET
TP8
U4B-13
U2B-12
PWR ON RESET
TP8
U12B-4
U5C-6
TP9
U11B-11
U5C-6
TP9
U11B-10
U5B-4
Motor drive counter clock
TP10
U14-5
U5B-4
Motor drive counter clock
TP10
P1-38
U5A-2
TP11
INVALID ADDRESS
U11C-1
U5A-2
TP11
INVALID ADDRESS
U6B-1
U5F-13
TP12
U13A-6
U5F-13
TP12
U6A-5
U13A-5
TP13
U6A-5
U20C-4
TP13
U6B-3
U20A-9
TP14
U13B-8
U5D-9
DATA STB
TP15
U13B-8
U6A-11
DATA STB
TP15
U11A-6
U14-14
TP16
COUNTER RESET STB
U11A-6
COUNTER RESET STB
U7-14
TP16
U12C-8
U14-11
PARALLEL LOAD STB
TP17
U12C-8
TP17
U7-11
PARALLEL LOAD STB
ARIB-12
U11C-13
TP18
RF DET
ARIB-12
P1-3
TP18
RF DET
U12D-11
U20A-10
MTR DRIVE TIMEOUT
TP19
U12D-11
U20B-12
TP19
U20C-5
U12D-11
TP19
U20D-2
U12D-11
TP19
U3D-9
U12D-11
TP19
U21A-2
U12D-11
TP19
TP20
U21B-6
U16-5
B3 DATA
AR1A-7
MOTOR DRIVE CONTROL 200 HZ
TP21
U21A-1
|