2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 2.
To access coolant heater circuit breaker, remove right C02 cylinder access
cover. Refer to page 2-923. Disconnect battery power lead from 20A
circuit breaker. Place red probe in battery power lead. Ground black probe.
If multimeter indicates about 24 volts, go to step 3. If multimeter indicates
no voltage, repair battery power lead. Refer to page 2-371. If problem still
exists, troubleshoot battery power circuit. Refer to page 2-82. Connect
lead.
Disconnect lead 400 from 20A circuit breaker. Connect multimeter to 20A
Step 3.
circuit breaker receptacles. If multimeter indicates 0 ohms, go to step 4. If
multimeter indicates infinity, replace 20A circuit breaker. Refer to page
2-1029. Connect leads.
2-326