Click here to make tpub.com your Home Page

Page Title: MAINTENANCE OF HEATER INSTALLATION KIT--ELECTRICAL COMPONENTS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2350-238-20-1
2-180. MAINTENANCE OF HEATER INSTALLATION KIT--ELECTRICAL COMPO-
NENTS.
b. Inspection/Repair
a.
Removal
This task covers:
c.
Installation
INITIAL SETUP
General Safety Insructions
Materials/Parts
Assembled washer bolt
Assembled washer screw (2)
Gasket
Failure to remove or disconnect
Lockwasher (2)
batteries before connecting or
Lockwasher (2)
disconnecting any electrical wiring
Lockwasher (18)
harness or lead may result in injury or
Lockwasher (2)
damaged equipment.
Lockwasher (2)
References
TM 9-2350-238-24P-1
Equipment Conditions
2-640  Batteries disconnected
1 Remove two hexagon plain nuts (1), two
Iockwashers (2), two socket head cap-
screws (3), and two loop clamps (4) from
pyrometer panel assembly to thermo-
couple assembly electrical lead (5).
2-1029