2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Drain coolant from radiators to lower coolant below the safe level. Set
Step 2.
MASTER switch ON. If low engine coolant level warning light operates, go
to step 3. If low engine coolant level warning light fails to operate, replace
aeration detector unit. Refer to page 2-539. Set MASTER switch OFF. Fill
radiators with coolant.
Make sure MASTER switch is OFF before repairing electrical
circuits. Failure to observe this warning could result in injury to
personnel.
Disconnect electrical lead from low engine coolant level warning light.
Step 3.
Place red probe on pin A. Ground black probe. Set MASTER switch ON.
If multimeter indicates about 24 volts, go to step 4. If multimeter indicates
no voltage, repair lead 509A. Refer to page 2-371. Set MASTER switch
OFF.
2-202