TM 9-2350-238-20-1
2-65. MAINTENANCE OF AERATION DETECTOR.
This task covers:
b.
Inspection/Repair
a. Removal
d. Testing
c. Installation
INITIAL SETUP
Materials/Parts
Equipment Conditions
Lockwasher (5)
2-935  Hull engine compartment deck
Lockwasher
assembly lid removed
Cooling system drained (TM 9-2350-
238-10)
References
TM 9-2350-238-10
TM 9-2350-238-24P-1
NOTE
Retain screws removed from access
cover.
1 Remove two existing screws (1) and
access cover (2) from rate of flow control
(3).
NOTE
Tag all electrical leads to aid in
identification.
2 Disconnect three electrical leads (4) from
terminal (5).
2-539