2-13.
FUEL SYSTEM MAINTENANCE (CONT)
d. Quick Start (coant).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
5
WARNING
(cont)
Compressed air must not exceed 30 psi. Wear safetyglasses when drying parts with compressed air. Failureto do so could
cause serious injury to eyes and possi-ble blindness. If you hurt your eyes or if a foreignobject is blown into your eyes,
seek medical attentionimmediately.
b. All metal parts
Clean
Use cleaning solvent
except ether
P-D-680; dry with com-
valve (22)
pressed air
c. Tubes (12 and
Clean
Wipe with clean, dry cloth
15)
INSPECTION
6
a. Tubes (12 and
Inspect
Apply compressed air at 10
15) and
psi, check for obstruc-
atomizer (19)
tions. Replace tube if
obstructed, cracked, or
deteriorated
b. Wiring
Inspect
Replace if insulation frayed
or cracked, or conductor
corroded or broken
c. Ether valve
Inspect
Connect momentarily to 12
(22)
volt battery. If clicking
sound is not heard, valve
solenoid is defective.
Replace if defective
d. All other parts
Inspect
Replace if bent, cracked,
dented, or threads damaged
REASSEMBLY/INSTALLATION
7
Air clean-
a. Bracket (33)
Position
At first and second hole
er, left
(from left side) on air
side, rear
cleaner
b. Two capscrews
Install and
(31) and
tighten
locknuts (32)
2-101