TM 9-2320-285-24-1
2-13.
FUEL SYSTEM MAINTENANCE (CONT)
d. Quick Start (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL/DISASSEMBLY (cont)
3
Air inlet
a. Tube (15)
Disconnect
housing,
and remove
right side
b. Atomizer (19)
Remove
4
Air clean-
a. Crimp connector
Remove and
Cut wires (23 and 30) as
er, left
(29)
discard close as possible to
side, rear
connector (29)
b. Two capscrews
Remove
(20) and
bracket (21)
c. Ether valve
Remove
(22)
d. Clip (34)
Remove
From cap (35) chain; route
chain through hole in
bracket (26) to remove
clip (34)
e. Cap (35)
Remove
Slip cap chain through hole
in bracket (26)
f. Two locknuts
Remove
(24), cap-
screws (25),
and bracket
(26)
g. Two capscrews
Remove
Support bracket (33)
(31) and
locknuts (32)
h. Bracket (33)
Remove
CLEANING
5
a. Ether valve
Clean
Wipe with clean, dry cloth
(22)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe
vapors. Do not use near open flame or excessive heat and don't smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with large amounts of water. If contact
with eyes is made wash eyes with water and seek medical aid immediately.
2-100

Privacy Statement - Press Release - Copyright Information. - Contact Us