Table 7-1. Control Unit Performance Standards
Control Setting
Step
Test
Performance
No.
Test
Equipment
Procedure
Standard
Equipment
Under Test
1
N/A
POWER: OFF
a. Inspect all controls and
a. Screws, bolts, and nuts
mechanical assemblies for
must tight; none
loose or missing screws,
missing.
bolts, and nuts.
b. Inspect, enclosure for
a. Enclosure exterior and
dust, rust, corrosion, and
interior must be free of
damaged finish.
dust, rust, corrosion,
and damaged finish.
c. Inspect electrical
a. Electrical assemblies
assemblies for damaged
and parts must be free of
parts, frayed or broken in-
any visual signs of dam-
sulation, and for signs of
age.
damage to connectors.
d. Check fuses F1 and F2 for
a. F1. 2amperes.
proper rating.
b. F2, 1 ampere.
2
TS352B: A.C. 250V
POWER: ON
a. None.
a. AC POWER lamp
Operating mode switch:
should illuminate.
ACCESS
b. Connect TS 352B test
a. Meter should indicate
leads between terminals
input power, approxi-
L1-1 and-2.
mately 115 V ac.
3
TS352B: A.C. O1V
POWER: ON Operating
a. Connect TS352B test
a. Meter should indicate
mode switch: ACCESS
leads between TB -5 and
6.3 V ac minimum.
-6.
b. Remove fuse F1.
a. None
4
TS352B: +D.C. 50V
POWER: ON Operating
a. Connect TS352B negative
a. None.
mode switch: ACCESS
lead to TB2-4.
b. Connect TS352B positive
a. Meter should indicate at
lead to TB2-2.
least 24 V dc.
c. Install fuse F1.
a. Meter should indicate
between 26.5 and 30 V
dc.
d. Connect TS352B positive
a. Meter should indicate
lead to TB2-3.
19 to 21 V dce.
e. Connect TS352B positive
a. Meter should indicate
lead to TB2-5.
4.75 to 5.25 V dc.
f. Connect TS352B positive
a. Meter should indicate
lead momentarily to each
19 to 21 V dc at each
of the following test
test point.
points: AITP1, A1TP2,
A2TPI, A2TP2, A3TP1.
A3TP2, A4TP1, A4TP2,
ASTPI, ASTP2, A6TP1,
A6TP2, A7TP1, and
A 7TP2.
Operating mode switch:
g. None.
a. Alarm LED's A through
TEST/RESET, then
F should illuminate
SECURE
after expiration of exit
time delay.
h. Pull out door tamper
a. None.
switch to the alarm by-
pass position.
CAUTION
i. Install orange jumper
a. None.
Plus 20 V dc exits at terminal 4 of terminal boards
wires between
terminals
A-F. Exercise care to prevent grounding terminal 4
1, 2, and 3 on terminal
with screwdriver or jumper wires. A blown fuse (F2)
boards A through E, and
will result.
between terminals 8 and 9
on terminal board S.
Change 3 7-14.3