TM
9-2350-238-20-2
19
Install
two
electric
floodlights
(32
and
34) and secure with two packing gland
spring tension washers (35), two new
Iockwashers (36), and two hexagon plain
nuts (37).
20
Connect
floodlamp
to
ground
electrical
lead
(38)
to
electric
floodlight
(34).
21
Connect two electrical leads (39) to two
electric floodlights (32 and 34).
22
Install two loop clamps (40) and secure
with two assembled washer bolts (41).
23
Install two loop clamps (42) and secure
with two hexagon capscrews (43), two
new Iockwashers (44), and two hexagon
plain
nuts
(45).
2-289
|