TM
9-2350-238-20-2
2-18. REPLACING CABLE TERMINALS
AND CONNECTORS (CONT).
MALE
CABLE
CONNECTOR
1
Strip cable insulation
equal to depth of
ferrule well (1).
2
Slide shell assembly (2) over cable (3).
Insert cable (3) into ferrule well (1) and
3
crimp.
4
Place C-washer (4) over cable (3) at
crimped
junction
and
slide
shell
assembly
(2) over C-washer (4) and ferrule (5).
FEMALE CABLE
CONNECTOR
(WITH
WASHER)
1
Strip cable insulation approximately
0.125 in. (0.318 cm).
2
Slide shell assembly (1) and washer (2)
over cable (3).
Place cable (3) in cylindrical end of ter-
3
minal (4) and crimp.
4
Slide
shell
assembly (1) and washer
(2)
over
terminal
(4).
FEMALE
CABLE
CONNECTOR
(WITH
SLEEVE)
1
Strip cable insulation approximately
0.125 in. (0.318 cm).
2
Slide shell assembly (1) and sleeve (2)
over cable (3).
Place cable (3) in cylindrical end of ter-
3
minal (4) and crimp.
4
Slide shell assembly (1) and sleeve (2)
over terminal (4).
2-72
|