Make sure MASTER switch is OFF before repairing electrical components.
q
Failure to observe this warning could result in injury or death.
Failure to remove or disconnect the batteries before removing or installing any
q
electrical wiring harness or lead may result in injury or damaged equipment.
1 Disconnect ground cable assembly (1) from gas-particulate filter unit M8A3 (2).
2 Unscrew and disconnect connector (3) from gas-particulate filter unit M8A3 (2).
3 Disconnect hoses (4) from gas-particulate filter unit M8A3 (2).
4 Release hold down latch (5) and remove
gas-particulate filter unit M8A3 (2) from
frame assembly (6).
5 Remove four nuts (7), four Iockwashers
(8), four machine screws (9), frame
assembly (6), and ground cable assembly
(1) from weldment.