TM 9-2350-238-20-1
NOTE
Two nuts, two Iockwashers, and
mounting clamp removed in step 9
are supplied with mechanical speed-
ometer. Take care not to lose hard-
ware removed in step 9.
Remove two nuts (17), two Iockwashers
9
(18), and mounting clamp (19) from
mechanical speedometer (14). Remove
mechanical speedometer from driver's
instrument panel.
10
Remove two screws (20) and two loop
clamps (21 ) from tachometer flexible shaft
assembly (22).
11
Disconnect nut (23) on end of tachometer
flexible shaft assembly (22) from
tachometer drive (24).
12
Disconnect nut (25) on end of tachometer
flexible shaft assembly (22) from
tachometer shaft adapter (26), and
remove tachometer flexible shaft
assembly.
13
Disconnect nut (27) on end of tachometer
flexible shaft assembly (28) from
tachometer flexible shaft adapter (26).
14
Disconnect nut (29) on end of tachometer
flexible shaft assembly (28) from
mechanical tachometer (30). Remove
tachometer flexible shaft assembly.
NOTE
Nut and Iockwasher removed in step
15 are supplied with tachometer shaft
adapter. Take care not to lose nut
and Iockwasher removed in step 15.
15
Remove nut (31) and Iockwasher (32)
from tachometer shaft adapter (26).
Remove tachometer shaft adapter from
wall of driver's compartment.
2-1151
|