TM 9-2350-238-20-1
2-182. MAINTENANCE OF HEATER INSTALLATION KIT--ELECTRICAL WIRING (CONT).
1 Untag and connect plug connector (1) to pyrometer panel indicator light (2).
2 Install screw (3), new Iockwasher (4), cable terminal (5), and hexagon plain nut (6) on pyro-
meter panel assembly (7).
3 Untag and connect two shell connectors (8) to pyrometer panel toggle switch (9).
4 Untag and connect bulkhead disconnect to circuit breakers and electrical components branched
wiring harness (10) to driver's heater electrical control box shell connectors (11).
5 Untag and connect nine shell connectors (12) to line connections.
6 Install new gasket (13). Untag and connect bulkhead disconnect to circuit breakers and
electrical components branched wiring harness (10) to bulkhead receptacle assembly (14).
Secure receptacle connector (15) with four new Iockwashers (16) and four screws (17).
7 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-1048
|