TM 9-2350-238-20-1
3 Remove four screws (2) and four washers (3), and disconnect receptacle connector (4) from
bulkhead disconnect to master relay.
4 If damaged, remove gasket (5) from receptacle connector (4).
5 Remove battery to bulkhead disconnect cable assembly (6) from hull through battery
compartment.
DISASSEMBLY
For disassembly of wiring harness receptacle connector, refer to general maintenance, page 2-371.
1 Inspect for broken, damaged, or missing parts.
2 If damaged or missing, replace marker bands. Etch or stamp lead number on new band.
5 Repair is by replacement of authorized parts (TM 9-2350-238-24P-1).
REASSEMBLY
For reassembly of wiring harness receptacle connector, refer to general maintenance, page 2-371.
INSTALLATION
1 Install battery to bulkhead disconnect cable assembly (6) in hull through battery compartment.
2 If removed, install new gasket (5) on receptacle connector (4).
washers (3) and four screws (2).
4 Connect cable terminal (1) to battery lug terminal.
5 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-717
|