 |  TM 9-2350-238-20-1 1 Install intercom circuit bulkhead disconnect to slip ring branched wiring harness (1) in hull. 2 Install new gasket (2) on receptacle connector (3). 3 Install receptacle connector (3) with new gasket (2), washers (4), and four socket head capscrews (5) on bulkhead. 4 Install ground cable terminal (6) and screw (7) on bulkhead. 5 Connect driver's control box wiring harness plug connector (8) to receptacle connector (3). 6 Install ground cable terminal (9) and screw (10) on bulkhead. 7 Connect plug connector (11) to slip ring. 8 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps, clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure and all hardware is tight. 2-105. MAINTENANCE OF HORN TO WARNING RELAY WIRING HARNESS. d. Reassembly a. R e m o v a l This task covers: e. Installation b. Disassembly c. Inspection/Repair INITIAL SETUP Materials/Parts Electrical wire (figure D-2, appx D) References TM 9-2350-238-24P-1 Equipment Conditions 2-640 Batteries disconnected 2-952 Driver's seat removed General Safety Instructions Failure to remove or disconnect batteries before removing or installing any electrical wiring harness or lead may result in injury or damaged equipment. 2-695 | 