2 Install gasket (2) on receptacle connector (3).
3 Install receptacle connector (3) with gasket (2), four washers (4), and four socket head
capscrews (5) on bulkhead.
4 Connect plug connector (6) to receptacle connector (3).
5 Untag and connect shell connector (7) to line connection.
6 Untag and connect shell connector (8) to line connection.
7 Untag and connect shell connector (9) to line connection.
8 Untag and connect shell connector (10) to rectifier (11).
9 Untag and connect shell connector (12) to rectifier (11).
10 Untag and connect shell connector (13) to 15 AMP circuit breaker (14).
11 Untag and connect shell connector (15) to 20 AMP circuit breaker (16).
12 Untag and connect shell connector (17) to 15 AMP circuit breaker (18).
13 Untag and connect shell connector (19) to 15 AMP circuit breaker (20).
14 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or Iead is secure
and all hardware is tight.