6 If damaged, remove gasket (11) from receptacle connector (10).
7 Remove floor disconnect to bulkhead disconnect wiring harness (12) from hull.
For disassembly of wiring harness receptacle connectors, refer to general maintenance, page 2-371.
1 Inspect for broken, damaged, or missing parts.
2 If damaged or missing, replace marker bands. Etch or stamp lead number on new band.
4 Repair is by replacement of authorized parts (TM 9-2350-238-24P-1).
For reassembly of wiring harness receptacle connectors, refer to general maintenance, page 2-371.
Install floor disconnect to bulkhead disconnect wiring harness (12).
1
If removed, install new gasket (11) on receptacle connector (10).
2
Untag and connect receptacle connector (10) to floor disconnect receptacle, and install four
3
washers (9) and four screws (8).
4
If removed, install new gasket (7) on receptacle connector (6).
Untag and connect receptacle connector (6) to bulkhead receptacle, and install four washers (5)
5
and four screws (4).
Install wiring harnesses protection access cover (3), four new Iockwashers (2), and four
6
hexagon head capscrews (1) to hull.
7
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.