TM 9-2350-238-20-1
1
Install bulkhead disconnect to voltage regulator assembly wiring harness (1) in hull through
battery compartment.
2
Untag and connect shell connector (2) to generator charge indicator light line connection.
3
Untag and connect plug connector (3) to voltage regulator.
4
If removed, install new gasket (4) to bulkhead receptacle connector (5).
5
Untag and connect bulkhead receptacle connector (5) to bulkhead disconnect to generator field,
and install four washers (6) and four screws (7).
If removed, install new gasket (8) to bulkhead receptacle connector (9).
6
7
Untag and connect bulkhead receptacle connector (9) to bulkhead disconnect to generator
armature, and install four washers (10) and four screws (11).
8
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-99. MAINTENANCE OF FLOOR DISCONNECT TO BULKHEAD DISCONNECT WIRING
HARNESS.
This task covers:
a. R e m o v a l
d. Reassembly
b. Disassembly
e. Installation
c. Inspection/Repair
INITIAL SETUP
Materials/Parts
General Safety Instructions
Electrical wire (figure D-2, appx D)
Gasket (2)
Lockwasher (4)
Failure to remove or disconnect
batteries before removing or installing
References
TM 9-2350-238-24P-1
any electrical wiring harness or lead
may result in injury or damaged
equipment.
Equipment Conditions
2-640 Batteries disconnected
2-677
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |