TM 9-2350-238-20-1
Failure to remove or disconnect batteries before removing or installing any electrical
wiring harness or lead may result in injury or damaged equipment.
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
1
clips, ground screws, etc. Remove only the hardware which secures the wiring harness or lead
being removed.
Remove four screws (1) and four washers (2), and tag and disconnect bulkhead receptacle
2
connector (3) from bulkhead disconnect to generator armature.
If damaged, remove gasket (4) from bulkhead receptacle connector (3).
3
Remove four screws (5) and four washers (6), and tag and disconnect bulkhead receptacle
4
connector (7) from bulkhead disconnect to generator field.
If damaged, remove gasket (8) from bulkhead receptacle connector (7).
5
Tag and disconnect plug connector (9) from voltage regulator.
6
Tag and disconnect shell connector (10) from generator charge indicator light line connection.
7
Remove bulkhead disconnect to voltage regulator assembly wiring harness (11) from hull
8
through battery compartment.
DISASSEMBLY
For disassembly of wiring harness receptacle connectors and plug connector, refer to general
maintenance, page 2-371.
INSPECTION/REPAIR
1 Inspect for broken, damaged, or missing parts.
2 If damaged or missing, replace marker bands. Etch or stamp lead number on new band.
5 Repair is by replacement of authorized parts (TM 9-2350-238-24P-1).