8 Untag and connect two shell connectors (11) to fuel pump switch (12).
9 Install ground cable terminal (13) and screw (14) on bulkhead.
10 Untag and connect six shell connectors (15) to line connection.
11 Connect five shell connectors (16) to driver's instrument panel (17) at the following points:
a. Untag and connect shell connector to master switch (18).
b. Untag and connect shell connector to instrument switch (19).
c. Untag and connect two shell connectors to starter switch (20).
d. Untag and connect shell connector to line connection.
12 Install ground cable terminal (21) and screw (22) on bulkhead.
13 Untag and connect plug connector (23) to fan (24).
14 Untag and connect shell connector (25) to 15 AMP circuit breaker (26).
15 Untag and connect plug connector (27) to receptacle connector (28).
16 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-91. MAINTENANCE OF SUSPENSION LOCKOUT SYSTEM WARNING LIGHT
GROUND AND HORN GROUND ELECTRICAL LEADS.
This task covers:
a. Removal
b. Inspection/Repair
c. Installation
INITIAL SETUP
Materials/Parts
General Safety Instructions
Electrical wire (figure D-2, appx D)
References
TM 9-2350-238-24P-1
Failure to remove or disconnect
batteries before removing or installing
Equipment Conditions
any electrical wiring harness or lead
2-640 Batteries disconnected
may result in injury or damaged
2-952 Driver's seat removed
equipment.
2-659
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |