NOTE
Steps 4 thru 12 apply to the aft air
cleaner centrifugal fan.
4 Set MASTER and INST switches to OFF.
5 Remove six hexagon head capscrews (4)
and six Iockwashers (5).
6 Remove access cover (6) and gasket (7).
Disconnect connectors (8 and 9).
7
Loosen four hose clamps (10).
8
Remove blower inlet air duct hose (11 ) and blower outlet air duct hose (12).
9
Loosen self-locking nut (13) and hexagon head capscrew (14) until aft air cleaner centrifugal fan
10
(15) can be removed.
Remove aft air cleaner centrifugal fan (15), self-locking nut (13), and hexagon head capscrew
11
(14) from air cleaner blower clamp bracket (16).
Remove two hexagon head capscrews (17), two Iockwashers (18), and air cleaner blower clamp
12
bracket (16).