2-24. TUBE REDUCER TO TUBE FITTING.
Disconnect tube assembly, and remove tube
reducer (1) and preformed packing (2).
Install new preformed packing (2) and tube
reducer (1), and connect tube assembly.
2-25. TUBE NIPPLE TO TUBE FITTING.
Disconnect tube fitting, and remove tube nipple
(1) and preformed packing (2).
Install new preformed packing (2) and tube
nipple (1), and connect tube fitting.
2-26. STRAIGHT ADAPTER TO TUBE
FITTINGS.
Remove tube fitting locknut (1), sleeve spacer
(2), and straight adapter (3).
Install straight adapter (3), sleeve spacer (2),
and new tube fitting locknut (1).
Section VIl. UNIT MAINTENANCE INSTRUCTIONS
2-27. GENERAL. This section provides general repair methods and cleaning procedures. Special
repair and cleaning procedures are provided, as required, in the individual maintenance instructions.