TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 6.
Disconnect lead 415 from input side of AIR PURIFIER SWITCH. Place red
probe in lead 415. Ground black probe. Set MASTER switch ON. If
multimeter indicates about 24 volts, go to step 7. If multimeter indicates no
voltage, repair lead 415 between circuit breaker and AIR PURIFIER
SWITCH. Refer to page 2-371. Set MASTER switch OFF. Connect lead.
Step 7.
Disconnect lead 415 from output side of AIR PURIFIER SWITCH. Place
red probe in AIR PURIFIER SWITCH. Ground black probe. Set MASTER
switch ON. Set AIR PURIFIER SWITCH ON. If multimeter indicates about
24 volts, go to step 8. If multimeter indicates no voltage, replace AIR
PURIFIER SWITCH. Refer to page 2-1176. Set MASTER switch OFF. Set
AIR PURIFIER SWITCH OFF. Connect lead.
2-369
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |