2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 1.
Disconnect leads from pyrometer and thermocouple. Connect multimeter to
pyrometer leads. If multimeter indicates 0 ohms, go to step 2. If multimeter
indicates infinity, replace pyrometer. Refer to page 2-1053. Connect leads.
Step 2.
Connect multimeter to thermocouple leads. If multimeter indicates 0 ohms,
the pyrometer circuit is operating normally. If multimeter indicates infinity,
replace thermocouple. Refer to page 2-1029. Connect leads.