TM 9-2350-238-20-1
Remove lead 10 from 20A circuit breaker. Connect multimeter to 20A
Step 2.
circuit breaker receptacles. If multimeter indicates 0 ohms, repair lead 10.
Refer to page 2-371. If multimeter indicates infinity, replace 20A circuit
breaker. Refer to page 2-1029. Connect leads.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect lead 344 from AIR INTAKE FAN switch. Place red probe in lead
Step 3.
344. Ground black probe. Set MASTER switch ON. If multimeter indicates
about 24 volts, go to step 4. If multimeter indicates no voltage, repair lead
344 between AIR INTAKE FAN switch and 20A circuit breaker. Refer to
2-317
|