TM 9-2350-238-20-1
BB. AIR BOX HEATER.
Step 1.
Set MASTER switch ON. Hold PUMP AND HEATER IGNITER switch ON
while cycling PRIME ENGINE FUEL FILTERS/HEATER FUEL CYCLE ON
AND OFF switch ON and OFF for 10 seconds. If fuel pump bypass sole-
noid valve does not become energized, go to step 2. If air box heater fuel
supply solenoid valve does not become energized, go to step 4. If air box
heater fuel supply solenoid becomes energized, go to step 7. Set MASTER
switch OFF. Release PUMP AND HEATER IGNIITER switch. Release
PRIME ENGINE FUEL FILTERS/HEATER FUEL CYCLE ON AND OFF
switch.