TM 9-2350-238-20-1
Disconnect lead 317 from HYD PUMP/PTO CLUTCH switch. Place red
Step 3.
probe in lead 317. Ground black probe. Set MASTER switch ON. If
multimeter indicates about 24 volts, go to step 5. If multimeter indicates no
voltage, go to step 4. Set MASTER switch OFF. Connect lead.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
To access bulkhead disconnect, remove driver's seat, refer to page 2-952;
Step 4.
and remove driver's compartment aft cowl, refer to page 2-928. Disconnect
wiring harness at bulkhead disconnect. Install jumper wire to pin D and
plug socket D (lead 459). Place red probe in socket G (lead 317). Ground
black probe. Set MASTER switch ON. If multimeter indicates about 24
volts, repair lead 317 between HYD PUMP/PTO CLUTCH switch and
bulkhead disconnect. Refer to page 2-371. If multimeter indicates no
voltage, repair lead 317 between bulkhead disconnect and circuit breaker.
Refer to page 2-371. Set MASTER switch OFF. Remove jumper wire.
Connect wiring harness.
2-283
|