2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Remove lamp from clutch engaged indicator light. Refer to page 2-566.
Step 1.
Connect multimeter to contacts of lamp. If multimeter indicates about 1
ohm, install lamp and go to step 2. If multimeter indicates infinity, replace
lamp. Refer to page 2-566.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect lead 317A from clutch engaged indicator light. Place red probe
Step 2.
in lead 317A. Ground black probe. Set MASTER switch ON. If multimeter
indicates about 24 volts, replace clutch engaged indicator light. Refer to
page 2-566. If multimeter indicates no voltage, repair lead 317A between
HYD PUMP/PTO CLUTCH switch and clutch engaged indicator light. Refer
to page 2-371. Set MASTER switch OFF. Connect lead.