TM 9-2350-238-20-1
Step 1.
Set MASTER switch OFF. Remove lamp from instrument (switch) panel
light. Refer to page 2-578. Connect multimeter to contacts of lamp. If
multimeter indicates about 70 ohms, go to step 2. If multimeter indicates
infinity, replace lamp. Refer to page 2-578.
Make sure MASTER switch is OFF before repairing electrical
circuits. Failure to observe this warning could result in injury to
personnel.
Disconnect lead 40 from instrument (switch) panel light. Place red probe in
Step 2.
lead 40. Ground black probe. Set MASTER switch ON. If multimeter
indicates about 24 volts, repair instrument (switch) panel light assembly.
Refer to page 2-566. If multimeter indicates no voltage, go to step 3. Set
MASTER switch OFF. Connect lead.
2-271
|