TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 2.
To access electrical leads, remove driver's instrument (gage) panel. Refer
to page 2-571. Disconnect lead 27 from GEN WARNING light. Place red
probe in lead 27. Ground black probe. Set MASTER and INST switches
ON. If multimeter indicates no voltage, connect lead 27 to GEN
WARNING light and go to step 3. If multimeter indicates about 24 volts,
set MASTER and INST switches OFF and go to step 4.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect instrument (gage) panel wiring harness. Place red probe on
Step 3.
receptacle pin F (lead 27). Ground black probe. Set MASTER and INST
switches ON. If multimeter indicates about 24 volts, repair lead 27
between plug and GEN WARNING light. Refer to page 2-371. If multi-
meter indicates no voltage, repair lead 27 between receptacle and INST
switch. Refer to page 2-371. Set MASTER and INST switches OFF.
Connect wiring harness.
2-178
|