TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 4.
Disconnect cable (7) from battery post (4). Place red probe on battery
post (4). Ground black probe. If multimeter indicates less than about 24
volts, replace cable (9). Refer to page 2-640. If multimeter indicates
about 24 volts, go to step 5. Connect cable (7) to battery post (4).
Step 5.
Disconnect cable (9) from battery post (5). Place red probe on battery
post (4). Ground black probe. If multimeter indicates less than about 24
volts, replace cable (7). Refer to page 2-640. If multimeter indicates
about 24 volts and problem still exists, troubleshoot master switch circuit.
Refer to page 2-97. Connect cable (9) to battery post (5).
2-96
|