TM 9-2350-238-20-1
Table 2-3. UNIT TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
Hold
cylinder control valve (1) and remove safety pin (2).
b.
Pull release harness (3). Check for internal binding. If binding, replace
c.
cylinder control valve. Refer to page 2-1155. Firing pin (4) should
extend about 5/32 in. (4 mm). If not, notify direct support maintenance.
d.
Reset
cylinder control valve (1) by rotating control handle (5) in
direction of reset arrow on cover (6). Rotate control handle (5) until
safety pin hole alines with safety pin hole in cylinder control valve (1).
Install safety pin (2).
112. DRIVER'S AIR PURIFIER UNIT DOES NOT OPERATE.
Check motor ground lead for bad connection.
Step 1.
Clean ground connections with crocus cloth (item 10, a.ppx C). Tighten
ground connections.
Troubleshoot driver's air purifier circuit. Refer to Electrical Circuit Symptom
Step 2.
Index, page 2-92.
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING.
a. Before performing any electrical circuit troubleshooting, refer to page 2-43 and ensure that all
mechanical troubleshooting procedures have been performed.
b. The electrical circuit troubleshooting table lists the procedures necessary to inspect/repair
applicable electrical circuits.
c. If you have a problem with an electrical circuit which is not covered in the steps below, notify
your supevisor.
2-91
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |