TM 9-2350-238-20-1
Table 2-3. UNIT TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
DRIVER'S WINDSHIELD ENCLOSURE KIT
106. WINDSHIELD WIPER MOTOR DOES NOT OPERATE WHEN MASTER SWITCH AND
WINDSHIELD WIPER SWITCH ARE ON.
Check windshield wiper motor ground lead for bad connection.
Step 1.
Clean ground connections with crocus cloth (item 10, appx C). Tighten
ground connections.
Troubleshoot windshield wiper circuit. Refer to Electrical Circuit Symptom
Step 2.
Index, page 2-92.
107. WINDSHIELD DEFROSTER DOES NOT OPERATE WHEN MASTER SWITCH AND
WINDSHIELD DEFROSTER SWITCH ARE ON.
Check windshield defroster ground lead for bad connection.
Step 1.
Clean ground connections with crocus cloth (item 10, appx C). Tighten
ground connections.
Troubleshoot windshield defroster circuit. Refer to Electrical Circuit Symptom
Step 2.
Index, page 2-92.
OIL RESERVOIR HEATER KIT
108. OIL RESERVOIR HEATER DOES NOT OPERATE.
NOTE
Remove 24-volt power source from slave receptacle after
problem has been solved.
Connect 24-volt power source to slave receptacle near oil reservoir heater exhaust.
Troubleshoot oil reservoir heater circuit. Refer to Electrical Circuit Symptom Index, page
PERSONNEL VEHICULAR HEATER ASSEMBLY
109. PERSONNEL HEATER CONTROL BOX LIGHT DOES NOT OPERATE WHEN PRESS-
TESTED.
Troubleshoot personnel heater control box light circuit. Refer to Electrical Circuit
Symptom Index, page 2-92.
2-89
|